logo
Rumah ProdukSensor Gas

YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices

Sertifikasi
Cina ShenzhenYijiajie Electronic Co., Ltd. Sertifikasi
Cina ShenzhenYijiajie Electronic Co., Ltd. Sertifikasi
I 'm Online Chat Now

YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices

YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices
YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices

Gambar besar :  YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices

Detail produk:
Place of Origin: CHINA
Nama merek: YJJ
Model Number: 7C2H5OH-100
Syarat-syarat pembayaran & pengiriman:
Minimum Order Quantity: 1
Harga: dapat dinegosiasikan
Packaging Details: Canned
Delivery Time: 5 to 8 working days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 1500

YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices

Deskripsi
Pressure factor: < 0.02% signal /MBar Temperature: -20℃ ~ +50℃
Repeatability: 1% output signal Baseline extent: <±0.4μA
Long term drift: < 5% signal loss / year Load resistance: 10Ω
Menyoroti:

MST electrochemical ethanol sensor

,

gas leakage alarm sensor

,

7 series ethanol gas sensor

Product Description:

YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices

 

Features:

Reproducibility: 1% output signal

Operating temperature range: Linear, regression coefficient R = 0.999

Operating humidity range: 20°C to 50°C

Operating pressure range: 15% to 90% 6MH (no condensation)

Pressure coefficient: Atmospheric pressure ± 10%

Baseline range: < 0.02% signal/mBar

Long-term drift: < ±0.4 mA

Offset voltage: +300 mV (Note: Sensors with added offset voltage must be waited for after insertion into the instrument)

Load resistance: 10 ohms

Built-in filter: None

Life expectancy: 2 years (in air)

Shelf life: 1 year (from the date of shipment)

Output current polarity: Positive current (for defining the output current of carbon monoxide and hydrogen sulfide sensors)

Anti-interference characteristics:

Note: Calibration and testing must be conducted using the target gas (the gas to be measured) to ensure the accuracy of the detection and alarm equipment. The purpose of providing anti-interference data is to understand the cross-response characteristics of the sensor to certain other gases, rather than providing alternative gases for calibration: The response characteristics of cross-interference gases are not guaranteed to be linear, and there will be significant cross-gas sensitivity variations between sensor batches. Therefore, if cross-gas is used for calibration, the malt sensor cannot guarantee the accuracy of the detection and alarm equipment.

 

Specifications:

Pressure Atmospheric pressure ±10%
Pressure factor < 0.02% signal /MBar
Baseline extent <±0.4μA
Weight 5 g

 