logo
Rumah ProdukSensor Gas

Mipex-02-1-II-1.1A Infrared Gas Sensor For Detecting Methane (CH4) Concentration

Sertifikasi
Cina ShenzhenYijiajie Electronic Co., Ltd. Sertifikasi
Cina ShenzhenYijiajie Electronic Co., Ltd. Sertifikasi
I 'm Online Chat Now

Mipex-02-1-II-1.1A Infrared Gas Sensor For Detecting Methane (CH4) Concentration

Mipex-02-1-II-1.1A Infrared Gas Sensor For Detecting Methane (CH4) Concentration
Mipex-02-1-II-1.1A Infrared Gas Sensor For Detecting Methane (CH4) Concentration

Gambar besar :  Mipex-02-1-II-1.1A Infrared Gas Sensor For Detecting Methane (CH4) Concentration

Detail produk:
Tempat asal: Rusia
Nomor model: Mipex-02-1-II-1.1A
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: 1
Harga: dapat dinegosiasikan
Kemasan rincian: Kotak kertas
Waktu pengiriman: 3-5 hari kerja
Syarat-syarat pembayaran: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Menyediakan kemampuan: 5000pcs

Mipex-02-1-II-1.1A Infrared Gas Sensor For Detecting Methane (CH4) Concentration

Deskripsi
Kelembaban relatif: 98% Tekanan atmosfer: 80 - 120 kpa
Suhu: -10 hingga +40 °C (Grup I); -40 hingga +60 °C (Grup II) Dimensi keseluruhan: Φ20x16.6mm
Gas terdeteksi: CH4 Waktu Respons t90: <10 detik (versi cepat); <30 detik.
Menyoroti:

Methane gas sensor 1.1A

,

Infrared CH4 concentration detector

,

Gas sensor with warranty

 

                              Mipex-02-1-II-1.1A Infrared Gas Sensor For Detecting Methane (CH4) Concentration 

 

1. Product Features:

  • Ultra-low power consumption: Average power consumption is less than 5 mW, ideal for battery-powered portable detection devices and scenarios requiring long-term continuous operation.
  • Wide measurement range & high accuracy: Supports measuring up to 100% VOL methane (CH₄) and 100% LEL hydrocarbon (CₙHₘ, calibrated to propane C₃H₈); accuracy reaches ±0.1% VOL or 5% of reading for CH₄, and ±3% LEL or 5% of reading for C₃H₈, meeting strict industrial detection standards.
  • Strong environmental adaptability: Operates normally under relative humidity up to 98% (non-condensing) and temperature ranges of -10~+40°C (Group I) / -40~+60°C (Group II); almost no interference from humidity, suitable for harsh industrial and mining environments.
  • High safety level: Complies with multiple international explosion-proof standards (e.g., Ex ia I Ma/Ex ia IIC T5 Ga, UL913 Class I Division 1); features "ia" intrinsic safety protection without sintering, ensuring safe use in flammable and explosive areas.
  • Stable & low-maintenance: Resistant to "poisoning" gases that affect catalytic sensors; maintains long-term stability with simple calibration requirements, reducing equipment maintenance frequency and costs.
  • Easy integration: Built-in microcontroller and digital UART interface; compact size (Φ20x16.6mm without pins) and lightweight (5.5~16.6g based on material), enabling easy integration into various detection instruments and systems.

2. Product Applications:

  • Mining industry: Used in underground coal mines and metal mines to detect methane (CH₄) leaks, preventing gas explosions and ensuring the safety of underground operations and personnel.
  • Oil & gas sector: Applied in oil exploration sites, refineries, and natural gas pipelines to monitor hydrocarbon (CₙHₘ) and methane concentrations, avoiding fire or explosion risks from gas leaks.
  • Chemical & petrochemical industry: Integrated into safety monitoring systems of chemical plants and petrochemical facilities to track methane and carbon dioxide (CO₂) emissions, ensuring compliance with environmental and occupational health standards.
  • Power & utility industry: Used in power plants, water treatment plants, and wastewater treatment facilities to detect flammable gas leaks in equipment operation environments, protecting production safety.
  • Portable detection devices: Assembled into handheld gas detectors for on-site emergency testing in hazardous material (hazmat) handling, fire rescue, and biogas engineering scenarios, providing real-time gas concentration data.

Parameter

Description

Working Principle NDIR (Non - Dispersive Infrared)
Gas Sampling Method Diffusion
Detected Gases CH4 (with reduced cross - sensitivity to ethane), CnHm (calibrated to C3H8), CO2
Measurement Range Up to 100%VOL CH4; 100%LEL CnHm
Accuracy ±0.1%vol. or 5% of the reading value for CH4; ±3%LEL. or ±5% of the reading value for C3H8
Response Time T90 <10s (fast version); <30s
Working Power Supply Voltage 3.0 - 5.0 VDC
Output Signal Digital, UART
Power Consumption <5mW
Warm - up Time No more than 1 min
Relative Humidity Up to 98%
Atmospheric Pressure 80 - 120 Kpa
Temperature -10 to +40 °C (Group I); -40 to +60 °C (Group II)
Overall Dimensions Φ20x16.6mm (without pins)
Weight Stainless steel (standard) - 16.6g; Stainless steel (fast version) - 15.5g; Polycarbonate - 5.5g

 