YJJ CL2-B1 Chlorine Gas Secondary Development Module Sensor elektrokimia + Modul Digital Kondisi Sinyal

Sertifikasi
Cina ShenzhenYijiajie Electronic Co., Ltd. Sertifikasi
Cina ShenzhenYijiajie Electronic Co., Ltd. Sertifikasi
I 'm Online Chat Now

YJJ CL2-B1 Chlorine Gas Secondary Development Module Sensor elektrokimia + Modul Digital Kondisi Sinyal

YJJ CL2-B1 Chlorine Gas Secondary Development Module Sensor elektrokimia + Modul Digital Kondisi Sinyal
YJJ CL2-B1 Chlorine Gas Secondary Development Module Sensor elektrokimia + Modul Digital Kondisi Sinyal YJJ CL2-B1 Chlorine Gas Secondary Development Module Sensor elektrokimia + Modul Digital Kondisi Sinyal YJJ CL2-B1 Chlorine Gas Secondary Development Module Sensor elektrokimia + Modul Digital Kondisi Sinyal YJJ CL2-B1 Chlorine Gas Secondary Development Module Sensor elektrokimia + Modul Digital Kondisi Sinyal YJJ CL2-B1 Chlorine Gas Secondary Development Module Sensor elektrokimia + Modul Digital Kondisi Sinyal YJJ CL2-B1 Chlorine Gas Secondary Development Module Sensor elektrokimia + Modul Digital Kondisi Sinyal

Gambar besar :  YJJ CL2-B1 Chlorine Gas Secondary Development Module Sensor elektrokimia + Modul Digital Kondisi Sinyal

Detail produk:
Tempat asal: Britania
Nama merek: YJJ
Nomor model: CL2-B1
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: 1
Harga: dapat dinegosiasikan
Kemasan rincian: Paket kotak
Waktu pengiriman: 5-8 Hari
Syarat-syarat pembayaran: L/C, D/A, D/P, T/T, Western Union
Menyediakan kemampuan: 2200

YJJ CL2-B1 Chlorine Gas Secondary Development Module Sensor elektrokimia + Modul Digital Kondisi Sinyal

Deskripsi
Kepekaan: -600 ~ -1150 nA/ppm Resolusi: 0,02 ppm
Nol Point Drift: < 0,5% FS/Tahun Jangka hidup: 24 bulan
Lingkungan Operasi: -20 hingga +50°C; 15 - 90% RH, tanpa kondensasi Interferensi silang: NO2 SO₂, TIDAK
Catu daya: Tegangan DC9-24V Keluaran sinyal: Analog RS485 /4-20mA
Menyoroti:

sensor elektro-kimia gas klorin

,

Modul pengkondisian sinyal digital

,

Sensor gas YJJ CL2-B1

Deskripsi produk:

YJJ CL2-B1 Chlorine Gas Secondary Development Module Sensor elektrokimia + Modul Digital Kondisi Sinyal

 

Fitur:

CL2-B1 Modul Pengembangan Sekunder Gas Klor (CL2-B1 Sensor Elektrokimia + Modul Digital Kondisioning Sinyal)

 

> Catatan: CL2-B1 adalah sensor elektro-kimia telanjang asli; ** Modul pengembangan sekunder = sensor CL2-B1 + Sirkuit Kondisi Bias Elektro-kimia Khusus + MCU Signal Processing Board**,menyelesaikan konversi I-V, titik nol, kompensasi suhu, dan output sinyal digital/analog secara eksternal, terhubung langsung ke PLC, mikrokontroler, sistem kontrol industri,tanpa perlu melakukan kondisi arus lemah sendiri

 

I. Parameter yang mendasari badan sensor (Module CL2-B1)

{\cH00FFFF}Mengukur Gas {\cH00FFFF}Cl2 Gas Klorin

Prinsip Pengukuran. Sel bahan bakar elektrokimia tiga elektroda.

Rentang pengukuran 0 - 20 ppm

Pemakaian jangka pendek 60 ppm (tidak untuk penggunaan jangka panjang)

Sensitivitas -600 ~ -1150 nA/ppm.

Waktu Tanggapan T90

Resolusi 0.02 ppm.

Zero Point Drift < 0.5% FS / Tahun

Waktu hidup 24 bulan.

-- Lingkungan Kerja -- -20 hingga +50 °C; 15 - 90% RH, tidak ada kondensasi.

Interferensi silang NO2 interferensi positif yang signifikan; SO2, NO interferensi lemah.

 

II. Parameter listrik lengkap dari modul pengembangan sekunder (spesifikasi modul digital umum yang tersedia di pasar)

 

Tabel

Sumber Daya DC 9-24V rentang tegangan luas; konsumsi daya khas < 120mA

{\cH00FFFF}Sinyal Keluar (baik satu atau dua keluaran) {\cH00FFFF}1RS485 - Modbus - RTU (digital); analog 24-20mA.

4-20mA Pemetaan 4mA = 0ppm; 20mA = 20ppm

{\cH00FFFF}Rs485 default {\cH00FFFF}9600-8-N-1; alamat 1; alamat dan baud rate dapat dimodifikasi.

{\cH00FFFF}Data output modul {\cH00FFFF}Konsentrasi gas klorin (ppm), suhu sensor, status perangkat, bit kesalahan.

Ketepatan (seluruh mesin) ± 3% FS (termasuk sensor + kesalahan sirkuit)

Kecepatan pembaruan 1Hz; dapat dikonfigurasi.

Perlindungan. Papan sirkuit IP30, ruang sensor IP40.

Ukuran. Sekitar 85×55×35mm (bervariasi sedikit menurut produsen yang berbeda).

 

III. Register kunci Modbus-RTU (fokus utama untuk pengembangan sekunder)

 

Alamat registrasi Fungsi Jenis data Deskripsi

Klorin gas konsentrasi uint16 nilai asli, dikalikan dengan 10; Contoh: 125 → 12.5 ppm

0x0001 suhu internal modul int16 kali 10

0x0002 Status perangkat uint16 0 - normal 1 - sensor gagal 2 - titik nol abnormal

00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100 00x100

{\cH00FFFF} 0x0101 {\cH00FFFF} Pengaturan tingkat baud {\cH00FFFF} uint16 {\cH00FFFF} 0 = 9600, 1 = 19200...

 

Contoh pembacaan: Register 0x0000 mengembalikan `00C8`, desimal 200 → 20.0 ppm (skala penuh).

 

IV. Definisi Pin (Terminal 5 Pin Standar)

VCC+ 9-24VDC.

2 GND Power Ground

3 485-A

4 485-B.

5 4-20mA output.

 

Pertimbangan Utama untuk Pembangunan Sekunder

1Waktu polarisasi**: Modul harus polarisasi selama 2-4 jam sebelum menyalakan agar sensor elektrokimia stabil;sensor baru harus sepenuhnya terpolarisasi sebelum dikalibrasi dengan Alphasense.

2Bahaya Kondensasi**: Modul klorin tidak boleh memiliki kondensasi; kondensasi akan langsung menggoreng elektrolit elektrokimia dan merusak sensor secara permanen; dalam skenario kelembaban tinggi,Pengeringan dan penyaringan jalur udara tambahan diperlukan.

3. Gas Interferensi**: Pembacaan adalah tinggi palsu ketika ada NO2 (nitrogen dioksida) di lingkungan; perangkat lunak perlu melakukan kompensasi silang.

4. Kalibrasi titik nol**: Kalibrasi titik nol harus diselesaikan dengan memperkenalkan udara nol bersih; tidak diizinkan untuk secara paksa nol di udara dalam ruangan normal.

5. IST Versi Diferensiasi**: CL2-B1-IST (dengan chip penyimpanan + suhu internal) modul dapat membaca parameter sensitivitas pabrik asli, menyederhanakan kalibrasi;CL2-B1 biasa tidak memiliki chip IST dan membutuhkan penulisan sensitivitas secara manual.

6. Wiring**: Komunikasi RS485 dianjurkan untuk menggunakan pasangan tersusun berselindung; resistensi beban 4-20mA harus ≤ 500Ω.

 

Aplikasi

Kebocoran klorin di pabrik pengolahan air limbah, bengkel kimia, gas ekor scrubber, pemantauan pipa klorin, integrasi sistem PLC / DCS.

 

Jika Anda membutuhkan, saya dapat menyediakan:

1. Lengkapi instruksi membaca-menulis Modbus untuk modul;

2Rumus konversi 4-20mA;

3Tabel perbandingan dari CL2-B1 sensor telanjang vs CL2-B1 modul pengembangan sekunder.

 

Spesifikasi:

Gas yang Diukur CL2
Jangkauan pengukuran 0 - 20 ppm
Overload jangka pendek 60 ppm
Sensitivitas. -600 ~ -1150 nA/ppm
T90 Waktu respons < 60 tahun

 

YJJ CL2-B1 Chlorine Gas Secondary Development Module Sensor elektrokimia + Modul Digital Kondisi Sinyal