logo
Rumah ProdukSensor Gas

YJJ ETO-A1 Electrochemical Ethylene Oxide Sensor 0-100ppm for Medical Sterilization Room Leak Detection

Sertifikasi
Cina ShenzhenYijiajie Electronic Co., Ltd. Sertifikasi
Cina ShenzhenYijiajie Electronic Co., Ltd. Sertifikasi
I 'm Online Chat Now

YJJ ETO-A1 Electrochemical Ethylene Oxide Sensor 0-100ppm for Medical Sterilization Room Leak Detection

YJJ ETO-A1 Electrochemical Ethylene Oxide Sensor 0-100ppm for Medical Sterilization Room Leak Detection
YJJ ETO-A1 Electrochemical Ethylene Oxide Sensor 0-100ppm for Medical Sterilization Room Leak Detection YJJ ETO-A1 Electrochemical Ethylene Oxide Sensor 0-100ppm for Medical Sterilization Room Leak Detection YJJ ETO-A1 Electrochemical Ethylene Oxide Sensor 0-100ppm for Medical Sterilization Room Leak Detection YJJ ETO-A1 Electrochemical Ethylene Oxide Sensor 0-100ppm for Medical Sterilization Room Leak Detection YJJ ETO-A1 Electrochemical Ethylene Oxide Sensor 0-100ppm for Medical Sterilization Room Leak Detection YJJ ETO-A1 Electrochemical Ethylene Oxide Sensor 0-100ppm for Medical Sterilization Room Leak Detection

Gambar besar :  YJJ ETO-A1 Electrochemical Ethylene Oxide Sensor 0-100ppm for Medical Sterilization Room Leak Detection

Detail produk:
Tempat asal: Britania
Nama merek: YJJ
Nomor model: ETO-A1
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: 1
Harga: dapat dinegosiasikan
Kemasan rincian: Paket kotak
Waktu pengiriman: 5-8 hari
Syarat-syarat pembayaran: L/C, D/A, D/P, T/T, Western Union
Menyediakan kemampuan: 1500

YJJ ETO-A1 Electrochemical Ethylene Oxide Sensor 0-100ppm for Medical Sterilization Room Leak Detection

Deskripsi
Rentang Pengukuran: 0 ~ 100 ppm Kelebihan Beban Maks: 200ppm
Kepekaan: 2000 ~ 3200 nA/ppm @20ppm EtO, 20℃ T90 Waktu respons: <150 detik
Tegangan bias: +300MV Resolusi: <0,1 ppm
Suhu Operasional: -30℃ ~ +50℃ Tekanan: 80 ~120kPa
Menyoroti:

ethylene oxide sensor for medical sterilization

,

electrochemical gas sensor 0-100ppm

,

medical room leak detection sensor

Product Description: YJJ ETO-A1 Electrochemical Ethylene Oxide Sensor 0-100ppm for Medical Sterilization Room Leak Detection Features: Specification Model: ETO-A1 Target Gas**: Ethylene Oxide (EtO, C₂H₄O) Principle**: 3-electrode Electrochemical, A-series housing - Measurement Range: 0 ~ 100 ppm - Max Overload: 200 ppm - Sensitivity: 2000 ~ 3200 nA/ppm @20ppm EtO, 20℃ - T90 Response Time:

Rincian kontak
ShenzhenYijiajie Electronic Co., Ltd.

Kontak Person: Miss. Xu

Tel: 86+13352990255

Mengirimkan permintaan Anda secara langsung kepada kami (0 / 3000)